Méréstechnika

használt HP műszerek, kiegészitők, tartozékok

 

 

HP 8655A Synchronizer/Counter


Item Condition: USED
Price: 46.000 HUF + ÁFA



SPECIFICATIONS
Counter Characteristics

Range: 1 kHz to 520 MHz
Sensitivity:
100 m Vrms (-7 dBm), ac coupled into 50 ohms.
(Typically -20 dBm, 10 kHz to 200 MHz).

Maximum input:
ac: 707 m Vrms (+10 dBm) for accurate count.
dc: ?25 Vdc. Both inputs are protected with common fuse.
Count resolution
: 6-digit LED display
Mode Normal x10 EXPAND1
1 kHz to 10 MHz (EXTERNAL) 10 Hz 1 Hz
10 to 520 MHz (EXTERNAL & SYNCHRONIZE COUNT) 1 kHz 100 Hz

Accuracy
: ?1 count ? time base accuracy.

Time Base Characteristics

Frequency:
1 MHz temperature-compensated crystal oscillator.
Aging
(constant ambient temperature): 0.1 ppm/hr., 2 ppm/90 days.
Temperature:
?5 ppm from 0° to 50°C (Referenced to 25°C.)
Typical Overall Accuracy
(after 2 hours warm-up and within 3 months of calibration): Better than ? 2 ppm from 15° to 35°C (Option 001 higher stability time base available.)
Real Output:
1 MHz, nominally 0.5 volts peak-to-peak 500 ohms.
External Reference Input:
1MHz, nominally 0.5 volts peak-to-peak into 1000 ohms (Not available with Option 001 high stability time base.)

Synchronization Characteristics

Frequency Range:
10 to 520 MHz
Frequency Count Resolution:
1 kHz, or 100 Hz in x10 EXPAND.
Frequency Loccsan Resolution
: 1 kHz, depressing LOCK +500 Hz button allows a locked resolution of 500 Hz.
Frequency Accuracy
: same as time base accuracy.
Lock Time Duration
(after 5 minute warm-up, constant ambient): 45 min. typical
FM Rate While Synchronized
: 50 Hz to 25 kHz
FM Accuracy
(with 8654B only):
[Total FM Accuracy] = [8654B FM Accoracy] ? [Frequency Correction Error]
Frequency correction error2 is typically 4%

_________________________________________________________________

1 Will continue to accurately count from 1 to 10 MHz and from 100 to 520 MHz with loss of most significant digit (indicated by overflow light). Phase lock is not allowed.
2Frequency correction error is a function of the unlocked 8654B freqency drift. For optimum FM accuracy, this error may be eliminated by unlocking, retuning to the desired frequency, and relocking.

Kérdése van? Szeretné kipróbálni?

Megtisztel érdeklődésével.

Viletelné Markó Mária

Hívjon: 06-30-2307529

 



Weblap látogatottság számláló:

Mai: 9
Tegnapi: 16
Heti: 113
Havi: 339
Össz.: 71 170

Látogatottság növelés
Oldal: HP 8655A
Méréstechnika - © 2008 - 2024 - smtmerestechnika.hupont.hu

A HuPont.hu ingyen weboldal szerkesztő mindig ingyenes. A weboldal itt: Ingyen weboldal

ÁSZF | Adatvédelmi Nyilatkozat

X

A honlap készítés ára 78 500 helyett MOST 0 (nulla) Ft! Tovább »